Radiol. bras ; 48(6): 363-367, Nov.-Dec. 2015. tab, graf
Article in English | LILACS | ID: lil-771086

ABSTRACT

Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.


Resumo Objetivo: Derivar espectros filtrados de raios X de tungstênio utilizados em sistemas de mamografia digital por meio de simulações Monte Carlo. Materiais e Métodos: Espectros filtrados por filtro de ródio foram obtidos para potenciais do tubo entre 26 e 32 kV. Os valores de camada semirredutora (CSR) dos espectros filtrados simulados foram comparados aos valores obtidos experimentalmente com um detector de estado sólido Unfors modelo 8202031-H Xi R/F & MAM Detector Platinum e unidade base 8201023-C Xi Platinum Plus w mAs em um sistema Hologic Selenia Dimensions utilizado no modo radiografia direta. Resultados: Os valores de CSR calculados mostraram boa concordância quando comparados com os valores obtidos experimentalmente. A maior diferença relativa entre os valores de CSR calculados com Monte Carlo e os valores de CSR experimentais foi 4%. Conclusão: Os resultados demonstram que os espectros filtrados de raios X de ânodo de tungstênio e o código de Monte Carlo EGSnrc podem ser utilizados para determinar a dose glandular média em mamografia.

2.
Radiol. bras ; 47(6): 361-367, Nov-Dec/2014. tab, graf
Article in English, Portuguese | LILACS-Express | LILACS | ID: lil-732753

ABSTRACT

Objetivo: Avaliar a dose glandular média utilizando um detector de estado sólido e a qualidade da imagem de um sistema de radiografia direta a partir de objetos simuladores. Materiais e Métodos: Irradiações foram realizadas utilizando o controle automático de exposição e placas de polimetilmetacrilato com diferentes espessuras para o cálculo da dose glandular média. A qualidade da imagem foi avaliada por meio das estruturas visualizadas nas imagens dos objetos simuladores. Resultados: Considerando a incerteza das medições, os resultados de dose glandular média estão de acordo com os valores fornecidos pelo equipamento e com os níveis de referência adotados internacionalmente. Os resultados obtidos a partir das imagens dos objetos simuladores estavam em conformidade com os valores de referência. Conclusão: Este trabalho contribui para verificar a conformidade do equipamento em relação a dose e qualidade da imagem. .


Objective: To evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and Methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: Considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: The present study contributes to verify the equipment conformity as regards dose values and image quality. .

3.
Radiol. bras ; 46(2): 96-100, mar.-abr. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-673352

ABSTRACT

OBJETIVO: Verificar a viabilidade de filmes radiocrômicos como um dosímetro alternativo para estimativa da dose média em cortes múltiplos a partir dos perfis de kerma.MATERIAIS E MÉTODOS: Os filmes foram distribuídos em cilindros posicionados no centro e nas regiões periféricas de um objeto simulador padrão de abdome utilizado para dosimetria em tomografia computadorizada.RESULTADOS: Os valores de dose média em cortes múltiplos calculados foram 13,6 ± 0,7, 13,5 ± 0,7 e 18,7 ± 1,0 mGy para os valores de passo (pitch) de 0,75, 1,00 e 1,50, respectivamente.CONCLUSÃO: Apesar de os resultados mostrarem valores menores que o nível de referência de radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para exames de abdome, eles sugerem que há espaço para otimização dos procedimentos e uma revisão do valor para o nível de referência de radiodiagnóstico brasileiro.


OBJECTIVE: To evaluate the feasibility of using radiochromic films as an alternative dosimeter to estimate the multiple scan average dose on the basis on kerma profiles.MATERIALS AND METHODS: The radiochromic films were distributed in cylinders positioned in the center and in four peripheral bores of a standard abdominal phantom utilized for computed tomography dosimetry.RESULTS: Values for multiple scan average dose values corresponded to 13.6 ± 0.7, 13.5 ± 0.7 and 18.7 ± 1.0 mGy for pitch of 0.75, 1.00 and 1.50, respectively.CONCLUSION: In spite of results showing lower values than the reference level for radiodiagnosis (25 mGy) established by the Brazilian regulations for abdominal studies, it is suggested that there is room to optimize procedures and review the reference level for radiodiagnosis in Brazil.


Subject(s)
Humans , Male , Female , Dosimetry/methods , Kerma , Government Agencies , Guidelines as Topic , Tomography, X-Ray Computed/standards